| MOQ: | 1 |
| Price: | Negotiation |
| Standard Packaging: | Wooden box |
| Delivery Period: | 25 working days |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 10,000PCS per month |
40 KVA Online UPS Touch Screen LCD True Online UPS Industrial Online UPS Parallel Function
Online double-conversion technology
DSP-based high reliability
PFC with power factor up to 0.99
Flexible battery configuration (16–20 pcs)
Parallel operation up to 4 units with common battery
Intelligent multi-stage battery charging
LCD/LED status display
Built-in maintenance bypass
Handles 3-phase load imbalance
RS-232 communication, SNMP optional
Emergency Power Off (EPO) support
DESCRIPTIONS:
The RSUN DT33 Series is an online double-conversion UPS designed for demanding, mission-critical power environments. Featuring three-phase input and output, it adopts active PFC technology to deliver an input power factor of up to 0.99, improving efficiency and reducing stress on the power grid.
Its space-saving, high-power-density structure maximizes installation efficiency, while advanced DSP control enables accurate regulation, real-time monitoring, and comprehensive protection.
The DT33 effectively shields critical loads from power anomalies including voltage surges, sags, transients, harmonics, and frequency fluctuations, providing stable and uninterrupted power for continuous operation.
SPECIFICATIONS:
| Model | DT33-10K | DT33-20K | DT33-30K | DT33-40K | DT33-50K | DT33-60K | DT33-80K | DT33-100K | DT33-120K | DT33-160K | DT33-200K | DT33-300K | ||
| Capacity | 10kVA | 20kVA | 30kVA | 40kVA | 50kVA | 60kVA | 80kVA | 100kVA | 120kVA | 160kVA | 200kVA | 300kVA | ||
| Input | ||||||||||||||
| Rated Voltage | 380Vac (3 phase+N) | |||||||||||||
| Voltage Range | 304Vac ~ 478Vac (line voltage) full load; 304Vac ~ 228Vac (line voltage) load derated linearly from100% to 80% | |||||||||||||
| Frequency Range | 40Hz ~ 70 Hz | |||||||||||||
| Power Factor | ≥ 0.99@100% load;≥ 0.98@50% load | |||||||||||||
| THDi | <3% (100% linear load) ; <5% (100%nonlinear load) | |||||||||||||
| Output | ||||||||||||||
| Output Voltage | 380/400/415Vac (3phase+N); | |||||||||||||
| Voltage Accuracy | ±1%@balanced load;±5%@unbalanced | |||||||||||||
| THDu | ≤2% (100% linear load);≤4% (nonlinear load) | |||||||||||||
| Power Factor | 0.9 (1 optional) | |||||||||||||
| Frequency Range | ±2Hz(settable);±0.5Hz,±1Hz,±3Hz(settable) (Synchronizing Range) | |||||||||||||
| Frequency Range | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz (Battery Mode) | |||||||||||||
| Overload | < 105%, long run; < 110%, 60 min; 110~125% rated load, load 10 min; >125~150% rated load, load1 min; >150%, 200ms | |||||||||||||
| Crest Factor | 3:1 (maximum) | |||||||||||||
| Switching Time | 0 ms (Main power Battery) | |||||||||||||
| 1 ms (phase lock failure, <2ms interrupt occurs) (Inverter Bypass) | ||||||||||||||
| < 2 ms (Inverter ECO) | ||||||||||||||
| Efficiency | ||||||||||||||
| Inverter Mode | ≥95% | |||||||||||||
| ECO Mode | ≥99% | |||||||||||||
| Battery | ||||||||||||||
| Number | Long backup | 32; 30 ~ 44(±15~±22)(settable) | ||||||||||||
| Standard backup | (30~60)x7AH/9AH | (60~80)x7AH/9AH | NA | |||||||||||
| Charging Current | Capacity* 15%/N/12(N=±15-22) | |||||||||||||
| Charging Voltage | ± 13.65Vdc * N ± 1%(N=±15-22) | |||||||||||||
| Physical | ||||||||||||||
| Long backup | Size (mm) | 280 x 685 x 725 | 425 x 780 x 1200 | 600 x 800 x 1600 | 600 x 960 x 1600 |
600 x 1010 x 2000 |
600 x 1010 x 2000 |
|||||||
| Net Weight(kg) | 45 | 108 | 230 | 310 | 360 | 460 | / | |||||||
| Standard backup | Size WxDxH(mm) | 400 x 685 x 1000 | 425 x 780 x 1580 | NA | ||||||||||
| Net Weight(kg) | 62 (w/o battery) | 135 (w/o battery) | NA | |||||||||||
| Environment | ||||||||||||||
| Working Temperature | 0 ~ 40°C battery life will be shorten when temperature > 25°C | |||||||||||||
| Relative Humidity | 0~95% no condensation | |||||||||||||
| Altitude | 1000 meters no derate, > 1000 meters derating 1% for every 100 meters rise | |||||||||||||
| Noise | ≤ 60dB (A)@ 1 meter | |||||||||||||
| Management | ||||||||||||||
| Intelligent RS232/RS485 | Support Windows® 2000/2003/XP/Vista/2008,Windows® 7/8/10,Linux and MAC | |||||||||||||
| Optional | SNMP / Dry contact | |||||||||||||
Data & IT Infrastructure: Cloud platforms, data centers, server rooms
Telecommunications: Mobile base stations, exchanges, network facilities
Finance & Banking: Core systems, digital finance platforms, ATM networks
Transportation Systems: Airports, rail transit, smart traffic management
Public Sector & Security: Government data systems, emergency and safety control centers
Industrial Automation: Smart factories, automated production lines, industrial IoT
Energy & Utilities: Power grids, renewable energy systems, oil and gas monitoring equipment
Q1: Is it possible to order a UPS sample for testing?
Yes. We welcome sample requests for evaluation purposes, and multiple models can be combined within a single sample order.
Q2: How long does it take to prepare samples and mass production orders?
Sample units are typically ready within 5–7 days, while bulk production usually requires about 25 working days.
Q3: Do you have a minimum purchase requirement?
Our minimum order quantity is one unit, making it convenient for trials and initial testing.
Q4: What delivery methods do you provide and what are the transit times?
We ship via sea freight, DHL, FedEx, and other logistics partners. Transit time depends on the shipping method and destination.
Q5: What is the ordering process?
Simply provide your application details first. We will recommend a suitable solution and quotation. Production starts after sample confirmation and deposit receipt.
Q6: Can the UPS be customized with our brand logo?
Yes, OEM logo customization is available. Please confirm branding requirements before production begins.
Q7: What after-sales warranty do you offer?
All UPS units are covered by a 3-year warranty against manufacturing and functional defects.