MOQ: | 1 |
Price: | Negotiation |
Standard Packaging: | Wooden box |
Delivery Period: | 25 working days |
Payment Method: | L/C,T/T |
Supply Capacity: | 10,000PCS per month |
UPS 100kva UPS DSP For Telecom 208v 3 Phase Ups 100kva Online UPS 100KW self-load test function
DESCRIPTIONS:
The RSUN DT33 Series is an advanced three-phase UPS with true online double-conversion, engineered for demanding power environments. With built-in power factor correction, it achieves up to 0.99 input PF, maximizing efficiency and minimizing upstream impact.
Its compact high-density design saves space, while digital DSP control enhances system accuracy, reliability, and self-protection.
The DT33 safeguards critical loads from power disturbances such as surges, sags, transients, harmonics, and frequency variation, delivering stable, clean power without interruption.
SPECIFICATIONS:
Model | DT33-10K | DT33-20K | DT33-30K | DT33-40K | DT33-50K | DT33-60K | DT33-80K | DT33-100K | DT33-120K | DT33-160K | DT33-200K | ||
Capacity | 10kVA | 20kVA | 30kVA | 40kVA | 50kVA | 60kVA | 80kVA | 100kVA | 120kVA | 160kVA | 200kVA | ||
Input | |||||||||||||
Rated Voltage | 380Vac (3 phase+N) | ||||||||||||
Voltage Range | 304Vac ~ 478Vac (line voltage) full load; 304Vac ~ 228Vac (line voltage) load derated linearly from100% to 80% | ||||||||||||
Frequency Range | 40Hz ~ 70 Hz | ||||||||||||
Power Factor | ≥ 0.99@100% load;≥ 0.98@50% load | ||||||||||||
THDi | <3% (100% linear load) ; <5% (100%nonlinear load) | ||||||||||||
Output | |||||||||||||
Output Voltage | 380/400/415Vac (3phase+N); | ||||||||||||
Voltage Accuracy | ±1%@balanced load;±5%@unbalanced | ||||||||||||
THDu | ≤2% (100% linear load);≤4% (nonlinear load) | ||||||||||||
Power Factor | 0.9 (1 optional) | ||||||||||||
Frequency Range | ±2Hz(settable);±0.5Hz,±1Hz,±3Hz(settable) (Synchronizing Range) | ||||||||||||
Frequency Range | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz (Battery Mode) | ||||||||||||
Overload | < 105%, long run; < 110%, 60 min; 110~125% rated load, load 10 min; >125~150% rated load, load1 min; >150%, 200ms | ||||||||||||
Crest Factor | 3:1 (maximum) | ||||||||||||
Switching Time | 0 ms (Main power Battery) | ||||||||||||
1 ms (phase lock failure, <2ms interrupt occurs) (Inverter Bypass) | |||||||||||||
< 2 ms (Inverter ECO) | |||||||||||||
Efficiency | |||||||||||||
Inverter Mode | ≥95% | ||||||||||||
ECO Mode | ≥99% | ||||||||||||
Battery | |||||||||||||
Number | Long backup | 32; 30 ~ 44(±15~±22)(settable) | |||||||||||
Standard backup | (30~60)x7AH/9AH | (60~80)x7AH/9AH | NA | ||||||||||
Charging Current | Capacity* 15%/N/12(N=±15-22) | ||||||||||||
Charging Voltage | ± 13.65Vdc * N ± 1%(N=±15-22) | ||||||||||||
Physical | |||||||||||||
Long backup | Size (mm) | 280 x 685 x 725 | 425 x 780 x 1200 | 600 x 800 x 1600 | 600 x 960 x 1600 |
600 x 1010 x 2000 |
|||||||
Net Weight(kg) | 45 | 108 | 230 | 310 | 360 | 460 | |||||||
Standard backup | Size WxDxH(mm) | 400 x 685 x 1000 | 425 x 780 x 1580 | NA | |||||||||
Net Weight(kg) | 62 (w/o battery) | 135 (w/o battery) | NA | ||||||||||
Environment | |||||||||||||
Working Temperature | 0 ~ 40°C battery life will be shorten when temperature > 25°C | ||||||||||||
Relative Humidity | 0~95% no condensation | ||||||||||||
Altitude | 1000 meters no derate, > 1000 meters derating 1% for every 100 meters rise | ||||||||||||
Noise | ≤ 60dB (A)@ 1 meter | ||||||||||||
Management | |||||||||||||
Intelligent RS232/RS485 | Support Windows® 2000/2003/XP/Vista/2008,Windows® 7/8/10,Linux and MAC | ||||||||||||
Optional | SNMP / Dry contact |
Q1: Is it possible to place a sample order for the UPS?
A: Yes, we encourage sample orders to evaluate product quality. Mixed models within the sample order are acceptable.
Q2: What is the typical lead time for orders?
A: Sample preparation usually takes 5 to 7 days, while mass production requires approximately 25 working days.
Q3: Do you enforce a minimum order quantity (MOQ) for UPS purchases?
A: We offer a low MOQ policy, allowing orders starting from a single unit for sample evaluation.
Q4: What shipping methods do you offer, and how long is the delivery time?
A: We ship via sea freight, DHL, FedEx, or other preferred carriers. Delivery duration depends on the shipping method and destination.
Q5: What is the order process for the UPS?
A: First, share your specific requirements or application details. We will provide a customized quote based on your needs. After sample approval and deposit payment, we will initiate production.
Q6: Can my company logo be printed on the UPS units?
A: Yes, OEM branding is available. Please notify us before production begins to arrange logo customization.
Q7: What warranty do you provide for the UPS products?
A: Our products come with a 3-year warranty covering manufacturing defects and system performance.