RSUN Introduces 2KVA Rack Mount Online UPS for Data Centers, Telecom Networks and Critical IT Infrastructure
2026-05-18
RSUN POWER TECHNOLOGY CO., LTD is proud to introduce the RT-2KL, a high-performance 2KVA Rack Mount Online UPS designed to provide reliable power protection for servers, network equipment, telecom systems, security monitoring applications, and small to medium-sized data centers.
As businesses across Europe and South America continue to face power instability, voltage fluctuations, and unexpected outages, the demand for long-runtime UPS solutions has grown significantly. The RT-2KL addresses these challenges with advanced double-conversion online technology, ensuring uninterrupted power supply with 0ms transfer time for mission-critical equipment.
The RT-2KL delivers 2KVA / 2KW output power with a Power Factor of 1.0, enabling users to maximize available capacity while protecting sensitive IT loads. Its 2U rackmount design allows easy installation in standard 19-inch server racks, making it an ideal solution for edge data centers, enterprise server rooms, telecom cabinets, and network infrastructure projects.
One of the key advantages of the RT-2KL is its 72VDC external battery architecture. Unlike traditional UPS systems with limited internal batteries, the RT-2KL supports extended backup time through scalable external battery banks, making it particularly suitable for telecom operators, ISP networks, CCTV monitoring systems, and remote communication sites that require several hours of backup power.
Key Features of RT-2KL:
• 2KVA / 2KW Online Double Conversion UPS
• Power Factor 1.0 Output
• 0ms Transfer Time
• 95.5% Efficiency in Online Mode
• Up to 98.5% Efficiency in ECO Mode
• 72VDC External Battery Support
• Adjustable Charging Current from 1A to 12A
• Pure Sine Wave Output
• Wide Input Voltage Range (110V–300V AC)
• LCD Display with Real-Time Monitoring
• Optional SNMP Card for Remote UPS Management
• RS232, USB and EPO Communication Ports
The growing adoption of cloud computing, edge data centers, industrial automation, and smart city projects throughout Europe and South America is creating increasing demand for reliable rack mount UPS systems with long backup capability. The RT-2KL is engineered to meet these requirements while providing flexibility, high efficiency, and cost-effective ownership.
With more than 20,000 square meters of manufacturing facilities and a strong engineering team, RSUN POWER TECHNOLOGY continues to deliver OEM and ODM UPS solutions for distributors, system integrators, telecom contractors, and UPS brands worldwide.
For companies seeking a dependable 2KVA Rack Mount Online UPS, Long Runtime UPS, Server UPS, Telecom UPS, or External Battery UPS Solution, the RT-2KL offers a powerful combination of reliability, scalability, and performance.
About RSUN POWER TECHNOLOGY CO., LTD
RSUN POWER TECHNOLOGY specializes in Online UPS Systems, Rack Mount UPS, Modular UPS, Industrial UPS, Inverters, Telecom Power Solutions, and OEM/ODM Manufacturing Services for global partners. The company serves customers across Europe, South America, Asia, the Middle East, and Africa with customized power protection solutions.
View More
RSUN supply Reliable Online UPS Solutions for Latin American and South American Markets
2026-05-11
As demand for reliable power protection continues to grow across Latin America and South America, RSUN POWER is strengthening its supply of high-performance online UPS systems designed for unstable grid environments, voltage fluctuations, and long backup applications.
Many countries in Latin America experience frequent power interruptions, unstable voltage conditions, and generator-related power issues. These challenges create increasing demand for true online UPS systems in industries such as IT infrastructure, CCTV security, telecom, healthcare, retail, and industrial automation.
RSUN’s 1KVA to 10KVA online double conversion UPS solutions are specifically developed to support businesses operating in difficult power environments. With pure sine wave output, 0ms transfer time, wide input voltage range, and generator compatibility, RSUN UPS systems help protect sensitive equipment and ensure continuous business operation.
The company’s long backup UPS models with external battery support are becoming especially popular in South American markets where extended outages are common. These solutions are widely used for servers, networking equipment, telecom systems, POS terminals, monitoring systems, and small data centers.
“Our goal is to provide stable, cost-effective, and OEM-friendly UPS solutions for distributors and project partners across Latin America,” said a representative from RSUN POWER TECHNOLOGY CO., LTD. “We continue to support local partners with customized branding, flexible configurations, and reliable long-term supply.”
RSUN operates a modern manufacturing facility covering more than 20,000 square meters and is supported by an experienced engineering team. The company also maintains in-house PCB production and strict quality control processes to ensure product reliability and consistency for international markets.
With growing partnerships in Mexico, Peru, Chile, Colombia, Brazil, Ecuador, and other South American countries, RSUN is actively expanding cooperation with UPS distributors, system integrators, telecom contractors, and OEM partners seeking dependable online UPS suppliers from China.
Key features of RSUN online UPS systems include:
True online double conversion technology
Pure sine wave output
PF 1.0 high efficiency design
Wide input voltage range
Generator compatibility
External battery long backup support
Intelligent LCD display
SNMP remote monitoring options
OEM and private label support
As businesses across Latin America continue upgrading their power protection infrastructure, RSUN remains committed to delivering stable, efficient, and scalable UPS solutions for commercial and industrial applications.
For distributor cooperation, OEM inquiries, or project support, RSUN welcomes global partners to contact the company directly.
View More
How Isolation Transformer UPS Protects Industrial Equipment in Latin America?
2026-05-06
As power infrastructure challenges continue across Latin America, RSUN POWER has officially introduced its latest 6KVA Online UPS solution designed specifically for telecom, industrial, commercial, and IT applications in regions with unstable power grids.
The newly upgraded 6KVA Online UPS features a built-in isolation transformer and supports dual 110V and 220V output, making it an ideal backup power solution for mixed-voltage environments commonly found in Latin American countries such as Peru, Colombia, Chile, Ecuador, Bolivia, and Mexico.
Unlike conventional UPS systems, the RSUN 6KVA Online UPS adopts true double-conversion online technology, delivering pure sine wave output with 0ms transfer time to ensure uninterrupted operation for critical equipment.
The system is specially engineered for:
Telecom base stations
Server rooms
CCTV and security systems
Industrial automation
Medical equipment
Banking systems
ISP and network infrastructure
To address unstable utility power conditions in developing regions, the UPS supports an ultra-wide input voltage range and generator compatibility, significantly reducing battery switching frequency and extending battery lifespan.
One of the key advantages of this model is the integrated isolation transformer design, which provides:
Better electrical isolation
Enhanced equipment protection
Reduced electrical noise
Improved compatibility with sensitive loads
Stable output for industrial environments
In addition, the dual 110V/220V output configuration enables customers to power different types of equipment simultaneously without requiring additional voltage conversion devices.
The 6KVA UPS also supports:
PF 1.0 output
LCD intelligent monitoring
SNMP remote communication
External battery expansion
OEM and private label customization
Parallel redundancy options
According to RSUN engineers, the growing demand for reliable backup power systems in South America is being driven by telecom expansion, increasing digital infrastructure, and frequent grid instability.
“Many customers in Latin America require UPS systems capable of handling mixed voltage applications and generator environments. This model was developed specifically to solve those challenges,” said the RSUN technical team.
As a professional UPS manufacturer in China, RSUN POWER provides OEM/ODM services for global distributors, project contractors, and system integrators.
With over 20,000 square meters of manufacturing facilities and in-house PCB production capabilities, RSUN continues to expand its global presence in telecom power solutions and industrial UPS systems.
View More
How Long Can a 20KVA UPS Run a Server Room?
2026-04-27
In today’s digital world, even a few seconds of power interruption can cause serious downtime, data loss, and hardware damage. For businesses operating server rooms, choosing the right UPS (Uninterruptible Power Supply) is critical for maintaining stable and continuous operation.
One of the most common questions from IT managers, system integrators, and data center operators is:“How long can a 20KVA UPS run a server room?”
The answer depends on several key factors, including server load, battery capacity, runtime requirements, and UPS efficiency.
In this article, we’ll explain how to estimate UPS runtime, what affects backup duration, and how to choose the right 20KVA online UPS solution for your server room or data center.
What Is a 20KVA UPS?
A 20KVA UPS is a medium-capacity power backup system commonly used for:
Server rooms
Small and medium data centers
Telecom equipment rooms
Network infrastructure
Industrial control systems
Edge computing facilities
Modern online double conversion UPS systems typically provide:
20KVA / 20KW output power
Three-phase input and output
Zero transfer time
Stable voltage and frequency
Battery backup during power outages
A true online UPS continuously powers equipment through the inverter, protecting sensitive servers from:
Blackouts
Voltage fluctuations
Frequency instability
Harmonics
Power surges
The Key Factor: Server Room Load
UPS runtime is mainly determined by:
Battery Capacity ÷ Actual Load
A 20KVA UPS does NOT always run at full load.
For example:
Server Room Load
Typical Runtime
25% Load (5KW)
60 - 120 minutes
50% Load (10KW)
30 - 60 minutes
75% Load (15KW)
15 - 30 minutes
100% Load (20KW)
5 - 15 minutes
The lighter the load, the longer the backup time.
This is why proper UPS sizing is extremely important for server room design.
What Affects UPS Runtime?
Several factors influence how long a 20KVA UPS can support your servers.
1. Battery Bank Capacity
Battery capacity is the biggest factor.
A UPS with a larger external battery cabinet can provide much longer backup time.
Typical battery options include:
Internal batteries
External VRLA battery banks
Lithium battery systems
For example:
Small battery bank 10-15 minutes
Medium battery bank 30-60 minutes
Large battery bank several hours
Many data centers use external battery cabinets to extend runtime.
2. Actual Power Consumption
Not every server room consumes full 20KW power.
Typical loads include:
Blade servers
Storage systems
Routers and switches
Cooling control systems
Firewalls
Security systems
Reducing unnecessary equipment can significantly improve UPS runtime.
3. UPS Efficiency
High-efficiency UPS systems waste less energy.
Modern online UPS systems can achieve:
Up to 95% efficiency in inverter mode
Up to 99% efficiency in ECO mode
Higher efficiency means:
Longer runtime
Lower heat generation
Reduced electricity costs
4. Battery Type
Different battery technologies provide different performance.
VRLA Batteries
Most common and cost-effective.
Advantages:
Mature technology
Lower cost
Widely used in telecom and server rooms
Lithium Batteries
Increasingly popular in modern data centers.
Advantages:
Longer lifespan
Faster charging
Smaller footprint
Better energy density
How to Calculate UPS Runtime
A simplified runtime formula is:
Runtime = Battery Capacity ÷ Load Power
For example:
A 20KVA UPS with:
240V battery system
100Ah battery bank
Can provide approximately:
24,000Wh of stored energy.
If the server room load is:
10KW
Estimated runtime:
Around 2 hours (theoretical value before efficiency losses).
Actual runtime depends on:
Battery aging
Temperature
UPS efficiency
Discharge rate
This is why professional UPS suppliers often provide runtime charts or customized battery calculations.
Typical Server Room Applications for 20KVA UPS
A 20KVA online UPS is ideal for:
Small and Medium Data Centers
Supports:
Server racks
Core switches
Storage systems
Telecom Infrastructure
Provides backup power for:
Base stations
ISP rooms
Communication systems
Financial Institutions
Protects:
Banking systems
Transaction servers
Data processing systems
Industrial Automation
Supports:
PLC systems
SCADA
CNC machines
Factory control equipment
Why Online Double Conversion UPS Matters
For server rooms, line-interactive UPS systems are usually not enough.
A true online double conversion UPS provides:
0ms transfer time
Stable sine wave output
Continuous voltage regulation
Better protection for sensitive IT equipment
This is especially important for:
High-density server environments
Virtualization systems
AI computing infrastructure
Mission-critical applications
Should You Choose Longer Runtime?
Not always.
Most server rooms only need:
10 - 30 minutes backup time
Why? Because the UPS is often used to:
Bridge power outages
Support generator startup
Allow safe server shutdown
However, some applications require:
1–4 hours runtime
Long-duration battery backup
Remote telecom support
Choosing the correct runtime depends on your business continuity strategy.
Key Features to Look for in a 20KVA UPS
When selecting a UPS for a server room, consider:
True online double conversion
PF=1 output
Parallel redundancy support
Low THDi
Generator compatibility
Intelligent battery management
SNMP remote monitoring
Scalability for future expansion
These features improve reliability and reduce operational risks.
Why More Businesses Choose RSUN Power
RSUN Power provides advanced online UPS solutions for:
Data centers
Telecom infrastructure
Industrial automation
Healthcare facilities
Mission-critical systems
Our 20KVA 3 phase online UPS systems feature:
High efficiency up to 95%
Parallel redundancy support
OEM/ODM capability
Intelligent DSP control
Flexible battery configurations
With a 20,000㎡ manufacturing facility and over 500 engineering staff, RSUN Power supports global distributors, system integrators, and infrastructure projects worldwide.
So, how long can a 20KVA UPS run a server room?
The answer depends on:
Server load
Battery bank size
UPS efficiency
Runtime requirements
For most server rooms, a properly configured 20KVA online UPS can provide anywhere from 10 minutes to several hours of backup power.
Choosing the right UPS solution is not just about backup time, it’s about ensuring business continuity, protecting critical infrastructure, and minimizing downtime risks.
If you are planning a new server room or upgrading your existing power protection system, selecting the correct online UPS and battery configuration is essential for long-term reliability and operational stability.