MOQ: | 1 Unit |
Price: | Negotiation |
Standard Packaging: | Wooden box |
Delivery Period: | 30 days |
Payment Method: | T/T,Western Union |
Supply Capacity: | 10000PCS per month |
Ups 300kva Modular UPS System 300KW 3U Three phase Online UPS LCD hot-swappable, Monitor 60KVA / 50kVA UPS Power Module, Double DSP control
Scalable from 50 kVA to 1200kVA.
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
The RSUN PM Series represents a new generation of high-performance modular UPS solutions. It incorporates a dual-DSP architecture for real-time system control and true online double-conversion, ensuring seamless power protection for sensitive equipment.
Its modular design integrates advanced power electronics: current-balanced rectifier modules, dynamic synchronization, distributed control layers, and three-level inverter topology, all contributing to high system efficiency and robust fault handling.
Scalable, redundant, and maintainable without downtime, the PM Series meets the rigorous demands of mission-critical environments such as large-scale data centers, automation, and telecommunications.
FEATURES:
SPECIFICATIONS:
Model | PM200 | PM300 | PM500 | PM600 | PM840 | PM1000 |
System Capacity | 200kVA | 300kVA | 500kVA | 600kVA | 840kVA/840kW | 1000kVA/1000kVA |
Power Module Capacity | 50kVA | 50kVA | 50kVA | 50kVA | 60kVA/60kW | 62.5kVA/62.5kW |
No. of Modules | 4 | 6 | 10 | 12 | 14 | 16 |
Main | ||||||
Input Wiring | 3Ph+N+PE | |||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Input Power Factor | >0.99 | |||||
Total Harmonic Distortion | THDi<3% for linear full load, THDi<5% for nonlinear full load | |||||
Voltage Range | 304~478Vac(line-line) 100% load; | |||||
228V~304Vac (line-line) load derated from 100%-75% linearly | ||||||
Input Frequency | 40Hz~70Hz | |||||
Bypass | ||||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Voltage Range | Default Range +15%~-20%(+10%,+15%,+20%,+25%, +25%-10%,-15%, -20%, -30%,-40% can be set) | |||||
Input Frequency | ±1Hz,±3Hz,±5Hz can be set | |||||
Battery | ||||||
Input Voltage | ±240VDC (the number of batteries can be selected from 30 to 44) | |||||
Charging Power | 20% * Power Module | |||||
Charging voltage accuracy | ±1% | |||||
Output | ||||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Rated Frequency | 50/60Hz | |||||
Power Factor | 1 | |||||
Voltage Accuracy | ≤±1.0%@Steady ;≤±5.0%@ Transient | |||||
Dynamic response | <5% (20% - 80% -20% Step load) | |||||
Dynamic recovery time | < 20ms (0% - 100% -0% Step load) | |||||
THDu | THDu <1%(linear load),THDu<5%( non linear load), | |||||
Overload Capacity | 110% overload for 60 min; 125% overload for 10 min; 150% overload for 1 mins; | |||||
>150% overload for 200ms | ||||||
System | ||||||
Efficiency | >96.5% (Dual Switch mode) | |||||
Display | 10.4 inch Touch Screen+LCD+LED | |||||
IP | IP20 | |||||
Environment | Operating Temperature: 0-40℃;Relative Humidity 0-95%(No condensing) | |||||
Noise | <55dB@1 meter away | |||||
Dimension ( WxDxH mm) and Weight (kg) | ||||||
Cabinet Dimension | 600*850*2000 | 600*1100*2000 | 1000*1000*2000 | 1000*1000*2000 | 1800*850*2000 | 3600*1000*2000 |
Module Dimension | 440*720*130 (3U) | 440*720*174 (4U) | ||||
Cabinet Weight (KG) | 190 | 270 | 450 | 530 | 960 | 1100 |
Module Weight (KG) | 39 | 39 | 39 | 39 | 39 | 39 |
APPLICATIONS:
Optimized for demanding power environments, this UPS supports:
• Data centers and high-density compute infrastructure
• Telecom switching, ISP services, and signal relay stations
• Banking, trading systems, and digital financial platforms
• Government & tax infrastructure with critical uptime demands
• Medical systems including HIS, LIS, and diagnostic imaging
• Industrial processes: SCADA, robotics, and automation
• Sensitive electronics requiring low THD and stable voltage